Test Code RIBOS Ribosome P Antibodies, IgG, Serum

Reporting Name

Ribosome P Ab, IgG, S

Useful For

As an adjunct in the evaluation of patients with lupus erythematosus (LE)

 

Aids in the differential diagnosis of neuropsychiatric symptoms in patients with LE

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Specimen Volume: 0.5 mL


Specimen Minimum Volume

0.35 mL

Testing Algorithm

See Connective Tissue Disease Cascade (CTDC) in Special Instructions.

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reference Values

<1.0 U (negative)

≥1.0 U (positive)

Reference values apply to all ages.

Day(s) and Time(s) Performed

Monday through Saturday; 4 p.m.

Test Classification

This test has been cleared, approved or is exempt by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

83516

LOINC Code Information

Test ID Test Order Name Order LOINC Value
RIB Ribosome P Ab, IgG, S 53892-6

 

Result ID Test Result Name Result LOINC Value
RIB Ribosome P Ab, IgG, S 53892-6

Clinical Reference

1. Bonfa E, Golombek SJ, Kaufman LD, et al: Association between lupus psychosis and anti-ribosomal P protein antibodies. N Engl J Med 1987;317:265-271

2. Bonfa E, Elkon KB: Clinical and serologic associations of the anti-ribosomal P protein antibody. Arthritis Rheum 1986;29:981-985

Method Description

Affinity-purified ribosome P antigens are coupled covalently to polystyrene microspheres, which are impregnated with fluorescent dyes to create a unique fluorescent signature. Ribosome P antibodies, if present in diluted serum, bind to ribosome P antigen on the microspheres. The microspheres are washed to remove extraneous serum proteins. Phycoerythrin (PE)-conjugated, antihuman IgG antibody is then added to detect IgG anti-ribosome P antibodies bound to the microspheres. The microspheres are washed to remove unbound conjugate, and bound conjugate is detected by laser photometry. A primary laser reveals the fluorescent signature of each microsphere to distinguish it from microspheres that are labeled with other antigens, and a secondary laser reveals the level of PE fluorescence associated with each microsphere. Results are calculated by comparing the median fluorescence response for ribosome P microspheres to a 4-point calibration curve.(Package insert: Bioplex 2200 ANA Screen. Bio-Rad Laboratories, Hercules, CA 11/2011)

Analytic Time

Same day/1 day

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK

Method Name

Multiplex Flow Immunoassay

Secondary ID

87837